CVE-2024-12858
Remediation/Mitigation Strategy for CVE-2024-12858: Heap-Based Buffer Overflow in Delta Electronics CNCSoft-G2
This document outlines the remediation and mitigation strategies for CVE-2024-12858, a critical vulnerability found in Delta Electronics CNCSoft-G2.
1. Vulnerability Description
- Vulnerability: Heap-Based Buffer Overflow
- Affected Product: Delta Electronics CNCSoft-G2 Version 2.1.0.16 and prior
- Description: CNCSoft-G2 lacks proper validation of the length of user-supplied data before copying it to a fixed-length heap-based buffer. This allows for an overflow if the input data exceeds the buffer’s capacity.
- Attack Vector: An attacker could potentially execute arbitrary code in the context of the current process by enticing a target user to visit a malicious web page or open a malicious file specifically crafted to exploit this buffer overflow.
2. Severity
- CVSS Score: 8.4 (HIGH)
- CVSS v3.1 Vector: AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Severity Level: HIGH
- Impact:
- Confidentiality: Complete information disclosure.
- Integrity: Complete system modification.
- Availability: Complete denial of service.
- Reasoning: The potential for remote code execution with the privileges of the CNCSoft-G2 process makes this a critical vulnerability. A successful exploit could allow an attacker to gain complete control over the affected system.
3. Known Exploits
- Exploitability: High. While no specific exploit code is detailed in the provided information, the nature of heap-based buffer overflows means that proof-of-concept exploits and eventually, publicly available exploits are likely to be developed.
- Likelihood of Exploitation: Elevated, given the criticality of the affected system (CNC software) and the relative ease with which heap-based buffer overflows can sometimes be exploited.
4. Remediation Strategy
The primary remediation strategy is to update CNCSoft-G2 to a patched version provided by Delta Electronics. This patch should address the vulnerability by implementing proper input validation and preventing buffer overflows.
- Action: Immediately contact Delta Electronics support to inquire about the availability of a patched version of CNCSoft-G2. Request an emergency patch if one is not yet publicly available.
- Implementation: Follow Delta Electronics’ recommended upgrade procedures to install the patched version. Thoroughly test the updated software in a non-production environment before deploying it to the production environment.
- Verification: After the update, verify that the vulnerability is no longer exploitable using penetration testing or by re-attempting known exploit methods (if available).
5. Mitigation Strategy (Until Patch is Available)
If a patch is not immediately available, the following mitigation strategies should be implemented to reduce the risk of exploitation:
- Network Segmentation: Isolate the CNCSoft-G2 system on a separate network segment to limit the potential impact of a successful attack. Implement strict firewall rules to restrict network access to and from the system, allowing only necessary communication.
- Access Control: Restrict access to the CNCSoft-G2 system to only authorized personnel. Implement strong password policies and multi-factor authentication (MFA) where possible.
- User Awareness Training: Educate users about the risks of opening suspicious files or visiting untrusted websites. Emphasize the importance of verifying the source and integrity of all files before opening them.
- Web Filtering/Proxy: Implement a web filtering or proxy solution to block access to known malicious websites. Monitor web traffic for suspicious activity.
- Intrusion Detection/Prevention System (IDS/IPS): Deploy an IDS/IPS to monitor network traffic for exploit attempts targeting CVE-2024-12858. Configure the IDS/IPS to block or alert on suspicious activity. Consider enabling “virtual patching” capabilities, if available, on your IDS/IPS solution.
- Honeypots: Deploy honeypots on the network to detect and analyze potential attacks.
- Monitor System Logs: Continuously monitor system logs for suspicious activity, such as unexpected process crashes or unusual network connections.
- Disable Unnecessary Features: If possible, disable any unnecessary features or functionality in CNCSoft-G2 to reduce the attack surface.
- Consider Alternative Software (Temporary): If possible, and depending on operational needs, consider temporarily using alternative CNC software until a patch for CNCSoft-G2 is available.
6. Communication
- Internal Communication: Communicate the vulnerability and the implemented mitigation strategies to all relevant stakeholders, including IT staff, security personnel, and end-users.
- External Communication: Maintain contact with Delta Electronics support to stay informed about the availability of a patch and any other relevant updates. Report any suspected exploit attempts to Delta Electronics and ICS-CERT.
7. Ongoing Monitoring
Continuously monitor the effectiveness of the implemented mitigation strategies and adjust them as needed. Stay informed about new developments related to CVE-2024-12858 and adapt the remediation and mitigation plans accordingly.
Assigner
- ICS-CERT [email protected]
Date
- Published Date: 2025-03-13 17:15:26
- Updated Date: 2025-03-13 17:15:26